ENVIRONMENTAL TEST CHAMBERNPD Stability Test Chamber industrial environmental chamber
NPD Eco Technologies

NPD Stability Test Chamber

Model: NPD-247 | Precision Temperature & Humidity Control for Pharmaceutical Shelf-Life Studies

NPD Stability Test Chambers provide controlled climatic conditions for long-term, intermediate and accelerated stability studies. Designed for pharmaceuticals, cosmetics, food, packaging and chemical products, they combine precise temperature and humidity control with uniform airflow, programmable operation and data logging.

5°C to 60°CTemperature Range
5–90% RHHumidity Range
±0.2°CTemperature Accuracy
171–840 LAvailable Capacities
Available Models
STC-171STC-280STC-420STC-560BTI-STC-840

Custom chamber configurations available on request.

Precise Climatic ControlStable temperature and humidity
Touchscreen OperationProgrammable cycles and timers
Dual Turbo-Fan AirflowUniform chamber conditions
ICH-Oriented TestingLong-term and accelerated studies
Product Overview

Controlled Environments for Reliable Stability Studies

The NPD Stability Test Chamber maintains temperatures from 5°C to 60°C and relative humidity from 5% to 90%. It supports widely used ICH Q1A(R2) stability-study conditions including 25°C / 60% RH for long-term testing, 30°C / 65% RH for intermediate testing and 40°C / 75% RH for accelerated testing.

Dual turbo-fan circulation, high-accuracy sensors, programmable cycles and protective alarms support consistent operation over extended study periods. The equipment is suitable for pharmaceutical manufacturing, contract research organisations, quality-control laboratories, cosmetics, food products and packaging development.

Engineered for Precision

Key Features & Benefits

Consistent climate control and reliable monitoring for long-duration research.

01

Temperature Precision

5°C to 60°C range with ±0.2°C accuracy and ±1°C uniformity.

02

Humidity Regulation

5% to 90% RH range with ±2% RH accuracy and ±3% RH uniformity.

03

Intelligent Touchscreen

Programmable controller with auto-tuning, auto-stop and 0–24-hour day/night cycles.

04

Uniform Air Circulation

Dual turbo fans maintain consistent temperature and humidity throughout the test chamber.

05

Logging & Connectivity

Built-in RS-485 interface; RS-232 logging and optional Wi-Fi/LAN connectivity.

06

Sample Protection

Low-water alarm, automatic water supply, safety cut-offs and audio-visual alarms.

Technical Information

Technical Specifications

Compare the five chamber configurations provided in the product specification.

ParameterNPD-STC-171NPD-STC-280NPD-STC-420NPD-STC-560NPD-STC-840
Capacity171 L280 L420 L560 L840 L
Internal Size (W × D × H)505 × 415 × 830 mm570 × 550 × 875 mm700 × 640 × 900 mm700 × 700 × 1100 mm825 × 825 × 1200 mm
Temperature Range5–60°C5–60°C5–60°C5–60°C5–60°C
Temperature Accuracy±0.2°C±0.2°C±0.2°C±0.2°C±0.2°C
Temperature Uniformity±1°C±1°C±1°C±1°C±1°C
Humidity Range5–90% RH5–90% RH5–90% RH5–90% RH5–90% RH
Humidity Accuracy±2% RH±2% RH±2% RH±2% RH±2% RH
Humidity Uniformity±3% RH±3% RH±3% RH±3% RH±3% RH
Humidity Stability±2% RH or better±2% RH or better±2% RH or better±2% RH or better±2% RH or better
Temperature Sensor3-wire RTD3-wire RTD3-wire RTD3-wire RTD3-wire RTD
Humidity SensorCapacitiveCapacitiveCapacitiveCapacitiveCapacitive
InteriorSS 304SS 304SS 304SS 304SS 304
ExteriorCRCA powder-coatedCRCA powder-coatedCRCA powder-coatedCRCA powder-coatedCRCA powder-coated
TraysSS 304 perforatedSS 304 perforatedSS 304 perforatedSS 304 perforatedSS 304 perforated
Electrical Supply220–240 V AC, 50 Hz, 1-phase220–240 V AC, 50 Hz, 1-phase220–240 V AC, 50 Hz, 1-phase220–240 V AC, 50 Hz, 1-phase220–240 V AC, 50 Hz, 1-phase
Optional Lighting10,000 lux10,000 lux10,000 lux10,000 lux10,000 lux

Swipe sideways on mobile to view all five models. Specifications and customised requirements are subject to the final supplied configuration.

Study Workflow

How the Stability Chamber Works

Controlled and repeatable conditions throughout the study.

01

Prepare Samples

Arrange samples on stainless-steel perforated trays.

02

Set Conditions

Choose the study temperature, humidity and optional cycling programme.

03

Maintain Climate

Dual fans, cooling and humidity systems sustain uniform conditions.

04

Monitor & Record

Review alarms and export or log test data for study documentation.

Stability Programmes

ICH Q1A(R2) Study Conditions

Standard study settings referenced in the supplied product documentation.

25°C / 60% RH

Long-Term

25°C ±2°C and 60% RH ±5% RH.

30°C / 65% RH

Intermediate

30°C ±2°C and 65% RH ±5% RH.

40°C / 75% RH

Accelerated

40°C ±2°C and 75% RH ±5% RH.

The chamber is designed to support ICH/WHO stability programmes; the actual study, qualification and regulatory compliance must be verified independently.

Technology & Construction

Control, Monitoring & Durable Design

A programmable touchscreen controller manages temperature and relative humidity with auto-tuning, alarm functions and an adjustable 0–24 hour day/night timer. Built-in RS-485 communication and RS-232 data-logger support allow traceable measurements. Wi-Fi and LAN monitoring are optional.

The chamber features an SS 304 interior, powder-coated CRCA outer body, 80–150 mm double-wall PUF insulation, a CFC-free hermetic cooling system and dual turbo-fan circulation. An inner full-length glass door improves visibility while limiting disturbance to the test environment.

Safety provisions include low- and high-temperature cut-offs, high-humidity cut-off, low-water-level alarm, automatic water supply and audio-visual deviation alarms. Optional 10,000 lux illumination can support photostability-related workflows.

Industries Served

Applications & Use Cases

Reliable stability studies for research, production and quality assurance.

Pharmaceutical stability studies
Shelf-life & expiry-date support
Cosmetic & personal-care products
Food & beverage evaluation
Packaging integrity studies
Chemicals & biomedical samples
Contract research laboratories
Quality control & R&D
Nutraceutical stability testing
Common Questions

Stability Test Chamber FAQs

What temperature and humidity ranges does the chamber support?

The supplied configuration specifies 5°C to 60°C and 5% to 90% RH.

What chamber sizes are available?

The listed capacities are 171, 280, 420, 560 and 840 litres, with the corresponding internal dimensions shown in the specification table.

Can it support long-term and accelerated pharmaceutical stability studies?

The product documentation identifies typical ICH Q1A(R2) long-term, intermediate and accelerated storage conditions. Suitability depends on the required protocol, qualification and configuration.

Is remote monitoring available?

Built-in RS-485 and RS-232 data-logging support are listed. Wi-Fi and LAN data-communication options are also described.

What construction materials are used?

The chamber uses an SS 304 interior, CRCA powder-coated exterior and SS 304 perforated trays.

Is special illumination available?

Optional 10,000 lux illumination is listed for photostability-related applications.

NPD ECO TECHNOLOGIES

Need a Stability Test Chamber?

Share your required chamber volume, study conditions and application for technical configuration details and a quotation.

Get Product Quote ↗