Model: NPD-OZ-216 | Ozone-Based Sterilization Chamber

The NPD Ozone Sterilizer combines ozone gas treatment and UV-C irradiation for controlled disinfection of compatible laboratory equipment, instruments, glassware and packaging. Its programmable controls, stainless-steel construction and door safety interlock support controlled hygiene workflows in laboratories, cleanrooms and healthcare facilities.

735 LitresChamber Capacity
253.7 nmUV-C Wavelength
80 WTotal UV Lamp Power
5 RacksRemovable & Adjustable
Disinfection Technology
Ozone GasUV-C IrradiationProgrammable Cycles

Available construction and configuration options subject to technical confirmation.

Ozone + UV-CDual disinfection approach
Stainless SteelHygienic interior design
Door InterlockAutomatic disinfection cut-off
Cycle MonitoringControl, alarms and status indicators
Product Overview

Controlled Ozone and UV-C Disinfection

The NPD-OZ-216 is designed to support contamination-control procedures for laboratory equipment, glassware, instruments, packaging and critical-environment components. Ozone gas acts as an oxidising disinfectant, while integrated UV-C lamps operating at 253.7 nm provide an additional irradiation-based disinfection mechanism.

The cabinet is configured for programmable treatment cycles with ozone monitoring, a stainless-steel chamber and adjustable loading racks. An integrated ventilation system supports controlled removal of ozone after treatment. Appropriate cycle validation, material compatibility and clearance of residual ozone are important for safe operation.

Product Highlights

Key Features & Benefits

Designed for controlled cleaning and disinfection workflows.

01

Dual Disinfection Technology

Combines ozone generation with 253.7 nm UV-C lamps to provide complementary disinfection mechanisms.

02

Programmable Operation

Microprocessor/PLC-based control enables selected treatment cycles and automated timer operation.

03

Ozone Monitoring

Real-time ozone concentration monitoring supports process visibility and control.

04

Hygienic Chamber

Stainless-steel construction, adjustable racks and accessible surfaces support practical loading and cleaning.

05

Safety Door Interlock

The door system automatically cuts off disinfection when opened and includes audible and visual indicators.

06

Data & Connectivity

Specified data logging and USB/Ethernet capabilities assist quality documentation and operational review.

Technical Information

Technical Specifications

Specifications sourced from the supplied NPD Ozone Sterilizer product sheet.

ParameterSpecification
MakeNPD
ProductOzone-Based Sterilization Chamber
ModelNPD-OZ-216 (PDF specification table: NPDI-OZ-216)
ConstructionHigh-grade stainless steel
Disinfection ModeOzone gas + UV-C irradiation
External Dimensions700 mm (W) × 700 mm (D) × 1,500 mm (H)
Capacity735 litres
Rack Arrangement5 adjustable and removable racks
UV Lamp MakePhilips UV-C germicidal lamps
UV Wavelength253.7 nm
UV Lamp Power40 W per lamp; 80 W total
Lamp Voltage / Current94 V / 0.425 A
Lamp Life9,000 operating hours
UV TransmissionMore than 75–80% (as stated in PDF)
Display TypeMicrocontroller-compatible LCD (PDF specification)
Display Dimensions80 × 36 × 20 mm
Control SystemMicroprocessor / PLC-based; touchscreen HMI described in PDF
Door SafetyAutomatic disinfection cut-off on door opening
IndicatorsLED status light and audible buzzer
TimerFully automated cycle controller
Power Rating150 W
Input Voltage220 V AC ±15%
Frequency50 Hz ±2%
Humidity ToleranceBelow 50% RH
Interior MaterialSS 304 or SS 316 stainless steel, as configured
Exterior MaterialGI powder-coated or stainless steel, as configured

The PDF uses both NPD-OZ-216 and NPDI-OZ-216 model codes and describes LCD and touchscreen interfaces. Confirm the delivered controller and final model designation before publishing an official specification sheet.

Operating Sequence

How the Ozone Sterilizer Works

Illustrative operational stages; exact cycle parameters should follow the approved product manual.

01

Load Items

Place compatible items on the five adjustable racks and close the chamber door securely.

02

Set Treatment Cycle

Select the appropriate authorised disinfection programme using the controller.

03

Ozone & UV-C Exposure

The system applies the configured treatment cycle with monitoring and interlocked operation.

04

Ventilate & Unload

Complete the designated ozone removal or clearance phase and open only when the system indicates safe access.

Smart Operation

Control & Data Management

The source describes a microprocessor/PLC-based controller for cycle programming, disinfection parameter selection and real-time ozone monitoring. It also lists data logging with USB or Ethernet connectivity to support operational records and quality-system integration.

The technical specification table lists an LCD-compatible display, while the descriptive sections mention a touchscreen HMI. The selected controller variant should be checked before publishing model-specific interface claims.

Construction & Protection

Durable and Safety-Focused

The chamber uses an SS 304 or SS 316 stainless-steel interior, with powder-coated GI or stainless-steel exterior options. A gasket-sealed safety door interlock cuts off disinfection if the door is opened; LED and audible indicators communicate operating status.

An integrated exhaust and ventilation arrangement supports controlled ozone removal following treatment.

Safety note: Ozone is hazardous to inhale and UV-C can injure eyes and skin. Only authorised operators should use validated cycles and observe the equipment's interlocks, ventilation and ozone-clearance instructions. Do not infer sterilisation assurance for all organisms or materials without validated performance evidence.
Suitable Environments

Applications & Industries

For appropriately validated, material-compatible disinfection tasks.

Laboratory Instruments & Glassware
Hospitals & Healthcare Facilities
Pharmaceutical Facilities
Biotechnology Laboratories
Cleanroom Support Areas
Food Packaging Operations
Research & Quality Control
Controlled Environment Equipment
Industrial Hygiene Workflows
Frequently Asked Questions

Ozone Sterilizer FAQs

What disinfection technologies does this chamber use?

The specified configuration combines ozone gas and UV-C irradiation at a wavelength of 253.7 nm.

What is the storage capacity of the chamber?

The supplied technical table lists 735 litres and five adjustable, removable racks.

What happens if the door is opened during a cycle?

The door mechanism includes an automatic disinfection cut-off. Operators must still follow the approved ozone-clearance procedure before opening and unloading.

Does it include data logging?

Yes. The PDF describes data logging and USB/Ethernet connectivity. Exact software and interface configuration should be confirmed for the supplied unit.

What construction options are available?

The PDF describes an SS 304 or SS 316 inner chamber and a powder-coated GI or stainless-steel exterior, depending on configuration.

Can all equipment be treated with ozone and UV-C?

No. Material compatibility, suitability of the load, treatment cycle validation and applicable safety requirements must be checked before use.

NPD ECO TECHNOLOGIES

Need an Ozone Sterilizer?

Share your chamber capacity, material type and disinfection requirements for a configuration discussion and quotation.

Get Product Quote ↗